Abstract
Gamma Knife cone-beam computed tomography (CBCT) images are deteriorated by cone-beam artifacts whose magnitude increases along the superior direction. In this study, a novel scan trajectory compatible with the Gamma Knife CBCT system is optimized to reduce cone-beam artifacts, with the aim to replace the current 200-degree single-arc scan. Approach. Data sampling analysis with tomographic incompleteness maps indicates the level of undersampling across the field of view based on the geometry of the system and of a scan trajectory. Moreover, CBCT simulations are performed from a virtual phantom with disks aligned along the axial direction and from a CT reconstruction of a stereotactic end-to-end validation (STEEV) phantom. CBCT projections are simulated for a given scan trajectory through a polychromatic forward projection model with added noise and scatter, then the CBCT image is reconstructed using an iterative algorithm which minimizes weighted least squares. Main results. Both the incompleteness analysis and the CBCT simulations indicate adding lines to the current single-arc trajectory is more efficient to reduce cone-beam artifacts than adding more arcs, both in terms of number of additional projections and new artifacts. A line-arc-line trajectory with source axial steps of 3.5 mm removes virtually all cone-beam artifacts. The widths of the cone-beam artifacts created by the disks show a positive correlation between the artifact magnitude and the incompleteness value. Significance. A line-arc-line scan trajectory is promising to reduce cone-beam artifacts of the Gamma Knife CBCT images while being a compatible and reasonable trajectory for the current system design.
The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.
Read it on ReadSearch
Each opens after you create an account, and brings you back to this paper.
More in Biomedical Engineering
Integration of Spectral CT with PET and SPECT: Bringing Tissue Composition Information to Molecular Imaging
A General-Purpose Adaptable Foundation Model for Total-Body PET Kinetic Modelling
Scalable Production of Lead-212 and Actinium-225 Generators with Fusion Neutrons
Distinct Radiobiological Responses to BNCT in SAS Oral Squamous Cell Carcinoma and MCF-7 Breast Cancer Cells
The 2024 MRSI Data Processing and Quantification Challenge Synthetic Dataset
Get the few papers worth your time in Biomedical Engineering every morning.
ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.