Non-circular scan trajectories for reducing cone-beam artifacts in Gamma Knife CBCT images: a simulation study

Alexandra Alain-Beaudoin, Håkan Nordström, Luc Beaulieu and Joakim da Silva

Published
Source
OpenAlex
Published in
arXiv (Cornell University)
DOI
10.48550/arxiv.2609.28232
Original
Read it at the publisher
Topics
Biomedical EngineeringRadiology & Imaging

Abstract

Gamma Knife cone-beam computed tomography (CBCT) images are deteriorated by cone-beam artifacts whose magnitude increases along the superior direction. In this study, a novel scan trajectory compatible with the Gamma Knife CBCT system is optimized to reduce cone-beam artifacts, with the aim to replace the current 200-degree single-arc scan. Approach. Data sampling analysis with tomographic incompleteness maps indicates the level of undersampling across the field of view based on the geometry of the system and of a scan trajectory. Moreover, CBCT simulations are performed from a virtual phantom with disks aligned along the axial direction and from a CT reconstruction of a stereotactic end-to-end validation (STEEV) phantom. CBCT projections are simulated for a given scan trajectory through a polychromatic forward projection model with added noise and scatter, then the CBCT image is reconstructed using an iterative algorithm which minimizes weighted least squares. Main results. Both the incompleteness analysis and the CBCT simulations indicate adding lines to the current single-arc trajectory is more efficient to reduce cone-beam artifacts than adding more arcs, both in terms of number of additional projections and new artifacts. A line-arc-line trajectory with source axial steps of 3.5 mm removes virtually all cone-beam artifacts. The widths of the cone-beam artifacts created by the disks show a positive correlation between the artifact magnitude and the incompleteness value. Significance. A line-arc-line scan trajectory is promising to reduce cone-beam artifacts of the Gamma Knife CBCT images while being a compatible and reasonable trajectory for the current system design.

The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.

Read it on ReadSearch

Each opens after you create an account, and brings you back to this paper.

Already a reader? Sign in

All new papers in Biomedical Engineering

Get the few papers worth your time in Biomedical Engineering every morning.

ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.

Papers belong to their authors and publishers; every page here links to the original. All research topics