{DEMAND}: {A}n organic glass scintillator array for direct measurements of $(α,n)$ and $(p,n)$ reactions in inverse kinematics

G. Christian, B. J. Reed, G. Lotay, G. Bartram, S. Blackmore, D. T. Doherty, A. Katrusiak, J. Henderson, D. A. Hutcheon, A. Lennarz, M. Loria, J. O'Neill and 5 others

Published
Source
arXiv preprint, posted before peer review
Original
Read it at arXiv
Topics
Instrumentation & DetectorsNuclear Experiment

Abstract

We have developed an array of up to 20 organic glass scintillator detectors, each consisting of a $3~\mathrm{cm}\times3~\mathrm{cm}\times3~\mathrm{cm}$ scintillator cube coupled to a photomultiplier tube. Sensitive to neutrons from a few hundred keV to several tens of MeV, the array was designed for use with recoil separators in inverse-kinematics measurements of astrophysical $(α,n)$ and $(p,n)$ reactions. It provides a prompt start signal for identifying recoil-neutron coincidences from the recoil time of flight. We characterize eight detectors used in an inverse-kinematics measurement of $^{22}\mathrm{Ne}(α,n)^{25}\mathrm{Mg}$, using source and in-beam data. From the widths of $γ$-ray Compton-edge peaks at 311, 341, 477, and 1062 keVee, we find an energy resolution described by $\mathrm{FWHM}(E)/E=\sqrt{A^2/E+B^2/E^2+C^2}$, with $A=0.00(7)$, $B=0.0618(54)$, and $C=0.135(5)$. The time-difference spectrum of nearest-neighbor $γ$-$γ$ coincidences from a $^{22}\mathrm{Na}$ source (250--600 keVee) gives a FWHM coincidence timing resolution of $910(40)$ ps, corresponding to a single-detector resolution of $640(30)$ ps. Mixed neutron-$γ$ fields from the in-beam reaction and a $^{241}\mathrm{AmBe}$ source show pulse-shape discrimination with an $n$-$γ$ figure of merit $>1$ down to about 100 keVee. Below 100 keVee, the total neutron yield can still be extracted using two-Gaussian fits to energy-gated pulse-shape discrimination spectra. Monte Carlo simulations of the present $^{22}\mathrm{Ne}(α,n)^{25}\mathrm{Mg}$ measurement give a neutron singles detection efficiency of $1.56(45)%$, with uncertainty dominated by systematic effects in the simulation inputs.

The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.

Read it on ReadSearch

Each opens after you create an account, and brings you back to this paper.

Already a reader? Sign in

All new papers in Instrumentation & Detectors

Get the few papers worth your time in Instrumentation & Detectors every morning.

ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.

Papers belong to their authors and publishers; every page here links to the original. All research topics