arXiv preprint ·
Neutron spectrometry of (p,n) based neutron fields at the University of Helsinki using the NCT-WES single-moderator directional spectrometer
- Published
- Source
- arXiv preprint, posted before peer review
- Original
- Read it at arXiv
- Topics
Abstract
A tunable-energy neutron beam produced with up to 1 $μ$A / 10 MeV proton beam on a solid LiF target is available at the Department of Physics of the University of Helsinki for neutron metrology and research applications. This work presents the experimental characterisation of the neutron beams produced at the Helsinki Accelerator Laboratory, and the validation of the \texttt{MCNP6} and \texttt{GEANT4} radiation transport codes for simulating these neutron beams. The neutron spectra produced in the forward direction from 1960, 2040, and 2310 keV protons were measured using the NCT-WES single-moderator directional spectrometer. NCT-WES (Neutron Capture Therapy Wide Energy Spectrometer) is a recently developed single-moderator neutron spectrometer with a sharply directional response, and it is a very convenient instrument to characterise neutron facilities, as it determines the whole spectrum in a single exposure, and has a low sensitivity to room-scattering. The neutron fluence was also determined with the Berthold LB 6411 neutron monitor. The data acquired with NCT-WES were unfolded using the FRUIT unfolding code, starting from guess spectra obtained from \texttt{GEANT4} or \texttt{MCNP6} simulations. The unfolding analysis showed that both transport codes produced plausible spectra, \texttt{MCNP6} being more accurate for the 1960 and 2040 keV irradiations and \texttt{GEANT4} for 2310 keV. The measured values of energy-integrated neutron fluence agree satisfactorily with simulations as well as preliminary measurements with the LB 6411 neutron monitor.
The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.
Read it on ReadSearch
Each opens after you create an account, and brings you back to this paper.
More in Instrumentation & Detectors
Non-contact temperature sensing and optical scatter in cryogenically-cooled crystalline silicon
Unlimited-Range Absolute Distance Interferometry Outdoors via Tunable Synthetic and Pseudo-Supersynthetic Wavelengths: The TeleYAG-II Interferometer
Magnetic Johnson noise from arbitrarily shaped conductors: experimental validation of the fluctuation-dissipation finite-element method
{DEMAND}: {A}n organic glass scintillator array for direct measurements of $(α,n)$ and $(p,n)$ reactions in inverse kinematics
Localized anomaly detection with a calorimeter normalizing flow
Get the few papers worth your time in Instrumentation & Detectors every morning.
ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.