arXiv preprint ·
Where Does EEG Help Wearable Freezing of Gait Detection?
- Published
- Source
- arXiv preprint, posted before peer review
- Original
- Read it at arXiv
- Topics
Abstract
Freezing of gait (FoG) detectors built on inertial measurement units (IMUs) are accurate while the legs move, but they become unreliable when the legs are nearly still, which is exactly when akinetic freezing, voluntary stopping, and standing must be told apart. Electroencephalography (EEG) captures motor-planning activity that leg sensors cannot, but EEG is impractical for daily use. We ask where EEG helps: as an input at inference time, or only during pretraining, so that the deployed detector still needs only IMUs. We assemble a pretraining corpus of synchronized EEG and IMU recordings (5 datasets, 184 people, 94 hours) and compare six settings that differ only in the modalities used for pretraining and as model input, each with tuned hyperparameters and five independent pretraining runs. On the BXHC FoG dataset (leave-one-patient-out, 10 patients with FoG), adding EEG as input raises FoG F1 from 0.663 to 0.740 (9 of 10 patients improve), and the gain in ranking performance is confined to the quartile of windows with the least leg movement (AUROC +0.063). Pretraining the IMU encoder jointly with EEG improves an IMU-only detector both within the cohort (FoG F1 0.663 to 0.705) and when it is trained on a small cohort and tested on another (FoG F1 +0.083, all 10 test patients improve). Repeating the study with PD-only and healthy-only pretraining corpora, each with its own hyperparameter search, shows that IMU-based detection is robust to the corpus, whereas the benefit of aligning EEG with IMU requires both. Cross-cohort analysis further shows that detectors trained without annotated voluntary stops classify nearly all stops as freezing. Finally, on PD versus non-PD classification in three external datasets, joint EEG+IMU pretraining improves PD detection from walking EEG over EEG-only pretraining (AUROC 0.750 vs. 0.683), while IMU-based detection does not depend on the pretraining.
The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.
Read it on ReadSearch
Each opens after you create an account, and brings you back to this paper.
More in Machine Learning
Ensemble Classification and Cancer-Specific Gene Signatures from Quality-Aware Hybrid Gene Selection in TCGA RNA-Seq data
State-Augmented Learning for Post-Deployment Adaptation of Coexisting O-RAN Applications
Where Causal Discovery Breaks on Real Data: Measuring the Assumptions One Property at a Time
Information-Theoretic Design of Sparse Autoencoder-Based Steering
Integer-Exact Microscaling: Running MXFP4 Language Models on INT8 Matrix Units
Get the few papers worth your time in Machine Learning every morning.
ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.