Abstract
Pedicle screw placement is technically demanding in scoliosis treatment. High precision is required due to limited visibility, anatomical variability, and the risk of complications. Although robotic systems assist CT-based planning and execution, they still rely on ionizing intraoperative imaging and complex registration. This study proposes robotic pedicle drilling with real-time preventive breach detection using electrical bioimpedance sensing. Methods: We developed a robotic approach combined with a pedicle-drilling tool equipped with a proprioceptive electrical bioimpedance sensor developed by SpineGuard. A real-time detection algorithm was designed to analyze the electrical bioimpedance signal during drilling and identify abrupt changes in conductivity associated with potential breaches towards the spinal canal. The method operates without external devices or sensors. Results: The ex vivo experiments showed that the proposed method prevented breaches in 100 of the 51 drilling cases. These findings demonstrate the system's ability to detect potentially hazardous events during drilling and to stop the procedure before. The ex vivo experiments demonstrated that the proposed method prevented breaches in all 51 drilling cases. Conclusions: This work demonstrates the feasibility of robotic pedicle drilling with electrical bioimpedance sensing for real-time breach prevention. Using only the tool signal, the method eliminates the need for external sensing systems and supports safer pedicle screw placement.
The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.
Read it on ReadSearch
Each opens after you create an account, and brings you back to this paper.
More in Robotics
Are Frontier VLM Agents Ready to Be Robot Generalists? An Empirical Study with the Embodied Agent Arena
Mind the Refinement Gap: When Safe High-Level Robot Plans Produce Unsafe Executions
Lang3DSeg: Annotation-Free Open-Vocabulary 3D Segmentation with Point Transformers
A Passive AI System for Verifying Physical State on Automated Liquid Handlers
Kinematic MeanFlow: One-Step Action Generation Policy for Robotic Foundation Models
Get the few papers worth your time in Robotics every morning.
ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.