arXiv preprint ·

Single-shot coherent process tomography and mid-infrared polarimetry with undetected photons

Marthe Zeja, Wen-Zhe Yan, Zhibo Hou and Sven Ramelow

Published
Source
arXiv preprint, posted before peer review
Original
Read it at arXiv
Topics
Quantum PhysicsOptics

Abstract

Measurements with undetected photons infer properties of a probe beam that is never detected, transferring mid-infrared information onto silicon-friendly wavelengths. Tomography in this paradigm has so far relied on switched settings or scanned phases, referenced across a drift-sensitive campaign; no protocol reads all Jones parameters from one frame. We show that a folded nonlinear interferometer with a diagonally pumped crossed-crystal source performs coherent process tomography of the undetected beam in a single spectrometer frame: it reconstructs all seven parameters of the beam's round-trip Jones matrix, the coherent part of the channel. Birefringent group-delay walk-off, normally a calibration nuisance, acts as a frequency multiplexer: each Jones-matrix element is assigned its own carrier, a spectral fringe period paired with a detector port. Because the multiplexing exploits the down-conversion bandwidth rather than merely tolerating it, a single Fourier transform per detector trace returns all four moduli and all three relative phases across that bandwidth, i.e., the full round-trip Jones spectrum up to a global phase, with no scan or setting change (after a one-time reference frame). Simultaneity makes every relative phase immune to common-mode drift, and a dark carrier, a self-interference term that unitarity forces to vanish, provides a built-in null test. For realistic parameters of a periodically poled KTP source the scheme yields wavelength-resolved mid-infrared polarimetry across 3.5-4.2 microns (~80 spectral points per Jones element) on a silicon camera, extending to depth-resolved Jones matrices, i.e., polarization-sensitive optical coherence tomography with undetected photons. A Fisher-information analysis, the first we are aware of in undetected-photon tomography, sets the precision budget and compares delay multiplexing to sequential protocols at equal photon number.

The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.

Read it on ReadSearch

Each opens after you create an account, and brings you back to this paper.

Already a reader? Sign in

All new papers in Quantum Physics

Get the few papers worth your time in Quantum Physics every morning.

ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.

Papers belong to their authors and publishers; every page here links to the original. All research topics