arXiv preprint ·

NV-Reason-CT: 3D Visual Language Model for CT Analysis

Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon, Stephanie Harmon, Rikhil Makwana, Mariam Aboian, Sena Azamat, Ibrahim Ethem Hamamci, Sezgin Er, Bjoern Menze and 6 others

Published
Source
arXiv preprint, posted before peer review
Original
Read it at arXiv
Topics
Computer VisionArtificial Intelligence

Abstract

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

The authors’ abstract, as arXiv lists it. arXiv’s listings, abstracts included, are free for anyone to reuse.

Read it on ReadSearch

Each opens after you create an account, and brings you back to this paper.

Already a reader? Sign in

All new papers in Computer Vision

Get the few papers worth your time in Computer Vision every morning.

ReadSearch reads the new papers in your field each day and brings you the few worth reading, each with its key finding in a sentence.

Papers belong to their authors and publishers; every page here links to the original. All research topics